Vpx conduction cooled atr. 1/2 ATR to ARINC 404A; Conduction cooled card cage to accommodate 6 x VPX slots on 1” pitch; 2 x 1” pitch custom power supply slots; High performance fan, commercial fan, or no fan option “Blown” sidewalls to maximise thermal performance The Extreme Engineering Solutions XPand6200 Series Sub-1/2 ATR, Conduction- or Convection-Cooled Chassis Supporting Conduction-Cooled VPX and XMC or PMC Modules is a true Commercial-Off-The-Shelf (COTS) Rugged system, supporting many 3U VPX, XMC, and PMC modules without modifications to the chassis or backplane to accommodate I/O. Vpx conduction cooled atr

 
 1/2 ATR to ARINC 404A; Conduction cooled card cage to accommodate 6 x VPX slots on 1” pitch; 2 x 1” pitch custom power supply slots; High performance fan, commercial fan, or no fan option “Blown” sidewalls to maximise thermal performance The Extreme Engineering Solutions XPand6200 Series Sub-1/2 ATR, Conduction- or Convection-Cooled Chassis Supporting Conduction-Cooled VPX and XMC or PMC Modules is a true Commercial-Off-The-Shelf (COTS) Rugged system, supporting many 3U VPX, XMC, and PMC modules without modifications to the chassis or backplane to accommodate I/OVpx conduction cooled atr  View

58-170 – Specialized ATR chassis for rotary-wing UAV radar. Electronics goes hand in hand with packaging. 4 modules are cooled by liquid flowing through an integral heatsink. LCR engineers apply advanced design methods that continue to ensure field proven performance in mission criticalThe Pixus conduction-cooled ATRs come in standard 1/2 and 3/4 sizes for 3U or 6U boards. e. Available in 1/2, 3/4, 1 and 1 1/2 ATR tall long or tall short formats per ARINC 404A, ARINC 600 and IEEE 1101. Advanced airflow design distributes air across external fins in sidewalls. ANSI/VITA 48. From standard air cooled to conduction cooled systems, we carry enclosures suited for benign and harsh environments. Our product line up also includes 19” rackmount chassis for VPX, SOSA, VME, cPCI and ATCA. Begin a project with a fully-featured conduction-cooled heatframe assembly solid model, and utilize WaveTherm's qualification products to physically test new modules in their intended environment. 3U VPX, 1/2 ATR, Conduction Cooled. The 7SL-3500 VPX System is a modular Military Rugged ATR enclosure, geared for 3U OpenVPX designs. ATRATS06BUNXHTC4 - ELMA Electronic, Inc. Pixus also provides conduction-cooled and customized OpenVPX enclosure solutions. Revolutionary design allows for up to 175 Watts per slot of conduction cooling. 11 Slot SOSA Development System. from $1,575. The Air Transportation Rack is the standard form factor for aircraft board electronic. E190 - 2-Slot 3U CompactPCI/VPX Enclosure Aitech. Boards are inserted in the back of the chassis in a vertical orientation. ATR-5700 6-slot 3U VPX Rugged Air Cooled Enclosure. Dawn’s VPX Development System for 3U OpenVPX boards aligns well with the requirements specified within Draft 1. VPX/OpenVPX, Other. Download AitechCatalog2015-16LR PDF for free. 6U Card Support (VPX/VME/cPci)- Aurora Chassis. 625 IN : Model Number: ATRCTS07ASNXLTQE4 : Norm. Our ATR (Air Transport Rack) enclosures are ideal for a variety of airborne applications, including ISR (intelligence, surveillance and reconnaissance), electronic warfare, SIGINT, and UAV radar. Products includes conduction cooled, air over conduction cooled and liquid cooled solutions for applications requiring 1-slot to 18-slots. C: -40 Operating. Elma’s line of rugged Air Transport Racks (ATRs) provide ideal cooling and reduced weight through superior design practices. Download PDF Report. The 1 ATR tall, short enclosure with independent dual liquid cooled side walls offers better cooling than conduction-only and air-flow designs, Elma officials say. 3 slot cPCI backplane and custom power supply connector. Products ATR Chassis ATR Chassis Trident offers a wide range of ATR chassis that are convection, conduction cooled, forced air conduction cooled and liquid cooled. Rhino Forced Air – Conduction cooled ATR Chassis. vpx conduction-cooled applications, four forced-air heat exchangers, low airflow resistance, dry-air contaminant free, high airflow rear exhaust fans, improved internal forced-air recirculation 6u 3u increased air convection +. I designed this 3U VPX 0. (See Figure 3. Output ripple <50mVp-p. Compliant with VITA 65 Specification. This Model Can be used to design the VITA Card Chassis. Liquid Cooled Server. Our Open Frame systems are available with air cooled or conduction cooled variants and 600W ATX power. or 1. 8 in. Today ATR’s are introduced into applications imagined never before, including surveillance, data collection, storage and weapons control. ). (H) Four 0. Elma's new liquid cooled chassis is available with a 6U OpenVPX backplane on a 1″ pitch per VITA 65 Backplane Profile BKP6-CEN07-11. Learn about our extensive line of rugged ATR chassis and integrated systems for VPX and SOSA aligned payloads. Power and reset LEDs are provided for. This emerging family of ATR chassis is designed to maintain safe operating temperatures for. Addressing the needs of users deploying custom boards for specialized applications, Carlo Gavazzi Computing Solutions' custom hybrid backplanes can accommodate VME64, VXS and VPX boards. Our product lineup includes conduction cooled, air / conduction and liquid / conduction cooled ATR solutions. 5 and 2 pounds. Rugged ATR chassis include conduction cooled VPX, air cooled VPX and liquid cooled VPX ATR solutions. View product Compare. ATR-3500 6-slot MicroTCA with cPCI and VPX Backplane options; OpenVPX 6U 10-slot Air Over Conduction 1200 Watts / Drive Bay. The Curtiss-Wright Defense Solutions rugged, conduction-cooled, network centric flight control and management computer is designed to operate in a rugged UAV environment and provides a total flight control solution backed by substantial technical maturity and heritage. Flexible, lightweight ATR specially designed for maximum cooling in airborne applications. Small and extremely rugged, cold plate base coupled, conduction cooled enclosure measures 9″L x 6″W x 7. Designed to maintain safe operating temperatures for high power 3U VPX and SOSA aligned conduction cooled systems. Open VPX. The chassis combines forced air with conduction cooling to dramatically increase thermal. 0, SATA, graphics, and RS-232/422/485. RuSH controlled power and cooling supports high current demands and corresponding high cooling. 12 x 12. or 1. 14 Slot VPX Conduction-Cooled System with Air Assist Part of our 1400 Series of conduction cooled enclosures with air assist, the 1440 is designed to maintain safe operating temperatures for high. Elma’s line of rugged Air Transport Racks (ATRs) provide ideal cooling and reduced weight through superior design practices. VPX361. 97"H Chassis Cooling: Conduction-Cooled, Natural Convection-Cooled Form Factor: 3U VPX, PMC, XMC Ethernet: Dependent on Configuration USB: Dependent on Configuration Serial: Dependent on Configuration Chassis Type: Sub-½ ATR Number of Slots: 2 Dimensions: 9. Download Datasheet View Product. Edge board with MIL-DTL-38999 circular connectors. With multiple high. 3U VPX 40G Ethernet Switch | Layer 2 Switching Conduction-cooled 3U VPX Ethernet switch module. Rhino - 3U/6U Liquid Cooled. 2-Slots of 3U VPX on 1″ pitch (OpenVPX Ready) Integrated intelligent Power Supply provides up to 400 Watts of 6-channel power. CCE-3VX2 3U VPX 2-slot CUBE Conduction Cooled; OpenVPX 6U 8-slot ATR Chassis; RME-6460 6U VPX 2-16 slots Rack Mount Enclosure. 3-n. Higher conduction means lower component temperatures . Most VPX systems make use of VITA 48. Serving military applications, Compact Network Storage (CNS4) system supports up to 4 Flash Storage Modules (FSM-C) in conduction-cooled ATR chassis for capacities up to 8 TB. Description Datasheet; D575. Elma Electronic Inc. 5-slot, 6U OpenVPX (VITA 65) backplane, 1-in pitch. 5, air flow-through, which has the advantage of being able to meter the air to specific cards. The AoC3U-412 brings removable drive bays to our ATR chassis line. Plug-in Module slot spacing is 1″. > Complies with conduction-cooled specification (VITA 48. GPC-3108: VMEbus 6UX160MM 8 slot card cage. This 3U Module enables an isolated thermal path Air Flow Through (AFT) – ANSI/VITA 48. 08 of Vita65. FEATURES AND BENEFITS • 5-slot full-mesh VPX backplane • 2 slots dedicated I/O daughtercards • VITA 46/48 and RoHSHartmann’s VPX Power Supplies are built for the most rugged applications with quality and reliability in mind. Number of Slots (1″ pitch): Various. Module Cooling: Conduction. See Hybricon’s Website for a complete line of 19” Rackmount Enclosures, ATR’s, and Custom Enclosures 1 877 HYBRICON. SYSTEM PLATFORMS OPENVPX ATR SYSTEM PLATFORMS ATR, VPX-REDI Liquid cooled ›› Conduction cooled ATR for VME, CompactPCI, VITA 41 (VXS), VITA 46 (VPX) and custom ›› Independent dual liquid cooled side walls ›› Modular design, field-proven high integrity frame construction ›› Cools in excess of 100 W per slot ›› In accordance. The heat from the internal conduction-cooled. CompactPCI Serial vs. 87"W x 3. Elma’s line of rugged Air Transport Racks (ATRs) provide ideal cooling and reduced weight through superior design practices. These PSUs are available in 3U or 6U form factor. 3U cPCI/VPX Conduction-Cooled Turnkey Subsystem Download Datasheet View Product. 2) payload cards and 1 of 3U VPX (VITA 62) PSU and protect them from the external environment. Min. For superior cooling performance, the Pixus RiCool chassis are ideal for 3U and 6U3U and 6URugged, mission critical and ATR enclosures for military, aerospace, commercial applications. The Air Transportation Rack is the standard form factor for aircraft board electronic equipment. BROCKTON, Mass. 0 in. 08 of Vita65. 8 in. 2 conduction cooled modules because of their established deployment track record. Circuit boards and electronic components are cooled more effectively as compared to other more traditional cooling methods such as air or conduction cooling alone. VPX plug-in LFT modules use liquid flowing through an integral heatsink of the module for cooling the circuit board. The Nova Integration Solutions 3000 Series consists of a family of custom and standard ATR reference designs and enclosures also referred to as a chassis, in support highly rugged and MIL spec applications required by the defence and aerospace markets. 9mm 269mm 389. Hybricon Corporation 12 Willow Rd. 3U/6U Short/Short, Short/Long, Tall/Short, Tall/Long & Dwarf to 1 ½ ATR Chassis. Form Factor: 3U VPX, PMC, XMC Ethernet: Dependent on Configuration USB: Dependent on Configuration Serial: Dependent on Configuration Chassis Type: Sub-½ ATR Number of Slots: 2 Dimensions: 9. Embedded RuSH technology actively monitors voltage, current and temperature and talks over system management bus using I2C. 1 ATR Liquid Cooled : Extended Description: This modular design ATR holds conduction cooled modules with independent dual liquid cooled side walls and a field-proven High Integrity Frame construction. 3-n. 1H00007411. 3U VPX, 1/2 ATR, Conduction Cooled. Folder. AUX-Clock and REF-CLK Input and output selectable through dip-switches. Thermal protection with auto recovery. Stock # 48364-1 . Learn about our extensive line of rugged ATR chassis and integrated systems for VPX and SOSA aligned payloads. 8 Air-Flow-Through (AFT) cooling standard, ensuring optimal performance for critical applications in the. The chassis incorporates a military grade high speed fan which provides air though sealed cooling channels on the side of the chassis. The majority of the VPX boards that are sold go into conduction-cooled systems. Sub-½ ATR, Conduction- or Convection-Cooled Chassis Supporting Conduction-Cooled VPX and XMC or PMC Modules. 8-compliant AFT modules use a finned heat-exchanger frame located within the central section of the assembly to top-cool primary circuit board and mezzanine board components (Figure 2). Conduction cooled 3 slot 3U VPX with integral 6 channel intelligent 400W power supply. C: 55 Altitude (1000 ft): 28. 5 CFM 27 CFM 40 CFM 54 CFM REAR FAN 84 CFM (Rugged) or 130/240 CFM (PX2) FRONT PANEL AREA 96 mm x 140 mm CM FRONT PANEL I/O 6 Power Pins (13 Amp) & 382 I/O Pins (5 Amp) Air assist cooling stretches VITA 48. This platform supports up to eight 0. Ltd. technologies such as the latest Intel Core i7 procsssor and 3U VPX" rlgure i, Many deployed C4ISR systems have to be packaged in conduction-cooled ATR enclosures The VPX (VITA 46) and 0penVPX (VITA 65) specifications support the design of conduction-cooled boards and systems like this one Ben Klam, VP o{ Engineering, andConduction- or Air-Cooled 3U VPX-REDI XMC/PMC Carrier Card. XChange3018. Open Frame Reduces System Design Time. The D575. 625 x 10. (H) Four 0. The XChange3031 delivers full wire-speed across all of its ports and supports jumbo frames up to 10 kB. This is in contrast to the traditional model of development for conduction-cooled systems, in which early work is performed using non-rugged, air-cooled cards that are mechanically and thermally incompatible. The 716 series conduction-cooled ATR enclosures, for example, are suitable for use with the 3U VPX REDI backplane. AIR ASSISTED, CONDUCTION COOLED ATR FEATURES • Conigurable for up to 7 slots of 3U VPX or CompactPCI modules with an additional 3U Vita 62 compliant power supply slot • OpenVPX supporting 10GB Ethernet • Flexibility to mount as either a base or side panel application. 8 uses air-flow-through cooling and its mechanical design supports air inlets at both card edges while routing air flow across the entire top surface of the boards. Built with aluminum the chassis are suitable for rugged airborne applications and can operate in under extreme temperatures, dust and humidity. , Nov. STD BACKPLANE VPX & cPCI-S 3U 1” pitch backplanes SLOT/BOARD FORMAT CCS: Conduction-cooled slots only for conduction-cooled ANSI-VITA 48. 6 RS-232 Chassis Type: Sub-½ ATR Number of Slots: 6 Dimensions: 13. Trident offers a wide range of ATR chassis that are convection, conduction cooled, forced air conduction cooled and liquid cooled. 8-inch slots • Physical dimensions of 4. 3 hardened form factor as well as heat exchanged versions. Component Type: Chassis / Enclosures Chassis Type: ATR Chassis Cooling: Baseplate Module Cooling: Conduction Number of Slots (0. 2 conduction-cooled modules due to an established deployment track record. XChange3000 (90030100) - Conduction- or Air-Cooled 3U VPX-REDI XMC/PMC Carrier Card; XChange3013 (90030320) - 3U VPX Gigabit Ethernet Switch with Optional Layer 2 Switching and Layer 3 Routing Management Support;. Environment. 88 in. Power Supplies. This modular design ATR holds conduction cooled modules with independent dual liquid cooled side walls and a field-proven High Integrity Frame construction. 950 inch Standard Conduction Cooled VITA Card in SOLIDWORKS. The. Elma's new liquid cooled chassis is available with a 6U OpenVPX backplane on a 1" pitch per VITA 65 Backplane Profile BKP6-CEN07-11. Features include 4 GbE ports, 3U VPX slot for additional I/O, and support for Universal Capture Card (UCC) XMC module. ATR Chassis, Top Loaded for 3U OpenVPX, Conduction Cooled Pixus Technologies Inc. com Website: Drawings Pixus offers various size configurations for the top loaded 1/2 ATR. Layer 2 or Layer 3. 8. Part of our AoC3U-800 Series of rugged packaging solutions, the AoC3U-821 enables high slot count systems in a precision engineered chassis for 3U VPX and SOSA aligned plug in card payloads. 2 wedge-lock boards 7STARLAKE scalable and. The VPX REDI backplane can be customized with multiple configurations for each unique embedded, development, testing, or measurement application. The chassis can accept a front and a Rear Transition Module (RTM). with our 3 Phase 3U VPX VITA 62 AC-DC . Three classes of products are provided – conduction cooled, convection. Power Supply Features. Advanced airflow design distributes air across external fins in sidewalls. The 12 slot power and ground backplane supports VITA 48. 88"W x 7. Backplanes are 100% configurable using Meritec cabling allowing. They are low-power system-on-chip (SoC. (W) x 5. Datasheet. E121 - 3/4-ATR Short VME Enclosure Aitech. Chassis Type: ATR Chassis Cooling: Forced Air Module Cooling: Conduction Number of Slots (1″ pitch): Various Operating Temp. Architecture. LIQUID / CONDUCTION COOLED CHASSIS CUSTOM 3U VPX VPXBACKPLANES DEVELOPMENT CHASSIS AoC-850 Rev 10-2020 Physical Thermal MIL-STD-704E,. Air / Conduction Cooled ATR Chassis with Removable Drives. Engineers’ Guide to VME, VPX & VXS Annual Industry Guide Solutions for VME, VPX & VXS system engineers Featured Products Elma’s VME RAIDStor…Check Pages 1-50 of AitechCatalog2015-16LR in the flip PDF version. To suit 3U & 6U card sizes. These 3U AC supplies boast a 600W air-cooled design with an internal fan and up to 88% efficiency. The chassis comes with different sizes and are equipped with various backplane options vis-à-vis 3U/6U. Categories: Enclosures:. Integrated Systems; ATR Systems for VPX;. 00 MTCA. Supports latest VITA 48. VPX Last 3U 1in Conduction Cooled 3D. Learn about our extensive line of rugged ATR chassis and integrated systems for VPX and SOSA aligned payloads. 87"W x 3. Module Name Standard ½ ATR Conduction Cooled System Configurations TSY-310X5 Digital Map with 2 Video Outputs and 1x MIL-STD-1553The Aitech E104 cold plate conduction-cooled VME computer enclosure is built to be rugged and reliable as well as lightweight and compact. This is a 3U 5HP wide (1-inch) module with guide block for use in VPX systems. This extends a. The XPort9200 supports a x1 PCIe XMC or 32-bit PCI PMC interface. The XPedite7370 also hosts numerous I/O ports including Gigabit Ethernet, USB 2. Airborne, shipborne and ground deployment. The ATR Chassis are compliant to MIL-STD-810F for shock and. Part of our AoC3U-800 Series of rugged packaging solutions, the AoC3U-821 enables high slot count systems in a precision engineered chassis for 3U VPX and SOSA aligned plug in card payloads. The versatile design allows multiple customizable configurations. 2) payload cards and 1 of 3U VPX. 8 ”PITCH1 FAC SP SX 0. slots. VPX / OpenVPX or custom desgi ns. 48. 2 module usage Configurable, modular ATR base design enables multi-program portability Forced air and conduction cooling for up to 850W of total power Dual 9 slot backplanes for up to 14 payload modules plus 2 each VITA 62 power modules and power hold up modules. The module requires a cold wall to dissipate the power or airflow over the ATR. A conduction-cooled ATR will typically be rated in excess of 50 W per slot. Utilizing our backplane design expertise, convection and conduction. Aitech Defense Systems E108 1/2 ATR Short VME Enclosure. 0 in. Sizes from 1/2 ATR to 3/4 ATR are available with various backplane slot counts for CompactPCI, VME64x, OpenVPX (VITA 46, VITA 48, VPX-REDI, or custom designs. IndiaMART. • 1/2 ATR tall, short • Holds 6, 3U x160mm conduction cooled cards (1in) • Customized front I/O panel • 6-slot OpenVPX backplane • No device mounting • 2 x 12 VDC fans @ 51 CFM each • 400 W fixed-mount 28 VDC power supply ATRATS06BUNXHTC4 VPX Optional Computing Products • 3U and 6U VPX compliant single board computers. RuSH controlled power and cooling supports high current demands and corresponding. The Extreme Engineering Solutions XPand6200 Series Sub-1/2 ATR, Conduction- or Convection-Cooled Chassis Supporting Conduction-Cooled VPX and XMC or PMC Modules is a true Commercial-Off-The-Shelf (COTS) Rugged system, supporting many 3U VPX, XMC, and PMC modules without modifications to the chassis or backplane to. The specification of 6U VPX calls for computer cooling via a conduction-cooled envelope compliant with the IEEE standard IEEE-1101. Chassis Manager PIC Other TRL-7: Prototype in Operational Environment. The VPX enclosures come in 1U-4U horizontal-mount (for 3U boards, 6U boards, or a mix), 4U-6U vertical-mount (for 3U cards), and 7U, 9U, and higher chassis (for 6U OpenVPX boards). Therefore, the chassis is fully sealed, but provides enhanced cooling. 3/4 ATR Air over Conduction Cooled Enclosure. Precision machined from 6061 T6 Aluminum. 97"H Chassis Cooling: Conduction-Cooled, Natural Convection-Cooled Liquid Cooled 1 ATR Chassis, Tall, Short Air Transport, Rugged, for 6U VPX Boards † 1 ATR platform with liquid cooled side walls, 6U conduction cooled boards, 1” pitch, per VITA 48. Also Available: A rugged ATR versionVPX ATR › › 1/2 Conduction cooled ATR for VME, CompactPCI, VITA 46 (VPX) and custom › › Modular design, field-proven › › In accordance with ARINC 404A › › Can accommodate up to 6 x 3U x 160 mm conduction cooled cards › › Pluggabe PSU › › I/O to customer specification › › Rear mounted fan providing cooling air flow. The 3U VPX power test module is a thermal load card for evaluating heat dissipation in a rugged conduction cooled VPX cage or chassis. $1,500. Effectively cooling 3U conduction-cooled modules and XMC cards – assuming each has 50 W chips on-card – to an 85 °C card edge requires a chassis with liquid cooling in the sidewalls. 6U VPX, Sealed Thermal Test Enclosure. 2. LoC3U-510 Extends System Cooling Capacity. Architecture. has a new rugged 1 ATR tall, short enclosure with independent dual liquid-cooled side walls that offers significantly better cooling than conduction-only and airflow designs. Air-Cooled Scroll Modular. Intel® Core™ i7 Processor-Based Conduction- or Air-Cooled 3U VPX-REDI Single Board Computer (SBC) The XPedite7371 accommodates up to 4 GB of DDR3 ECC SDRAM in two channels to support memory-intensive applications. Component Type: Chassis / Enclosures Chassis Type: ATR Chassis Cooling: Forced Air Module Cooling: Conduction Number of Slots (1″ pitch): Various Operating Temp. $2,623. For example, developments can begin on the bench with 6-slot air-cooled systems and then migrate to 12-slot 19" rack equipment or conduction-cooled ATR solutions while using the same plug-in card. TR MAx/6sd-RCx – Rugged 3U VPX Plug In Card. EMI/RFI Power Line Filtering. The VT976 provides conduction cooling for fan less operation in environments requiring very low acoustic and electrical emission. 2 (REDI) and VITA 65 (OpenVPX™) † 6U, 7-slot backplane, 1” pitch per VITA 65 Backplane Profile BKP6-CEN07-11. The liquid-cooled chassis sidewalls will support electronic modules each dissipating in excess of 150 watts. 3U ATR; HPC SERVER. 09in (175mm) W x 9. It also supports dual Gigabit Ethernet, GPIO, I²C, XMC I/O,. VPX VITA CARD 3U /. The Intel® Atom™ E3800 processors provide excellent computational performance and I/O functionality for their power profile and size. Architecture: VPX/OpenVPX : Cooling: Conduction-Cooled : Norm /MIL / NAS NumberWe also see customers asking for more small-form-factor ATRs where we primarily see 3U VPX conduction-cooled boxes. It is designed to house three 3U VPX (VITA 48. We offer a wide range of ATR chassis that are convection, conduction cooled and liquid cooled. 87"W x 3. 8" conduction cooled ruggedized VPX power supply, VITA 62 - SOSA aligned Version, 306W output power +12V/20A,. Airborne, shipborne and ground deployment; 3U/6U High ATR Chassis with upto 14 Slots Card Area; 3U/6U(VPX / cPCI/ VME) Backplane Options; 1ϕ / 3ϕ AC or 28v. The 7-slot air-cooled Chassis and Backplane incorporates slots for up to four conduction-cooled 3U VPX Payload Boards, plus a 100GbE Switch, SBC, and VITA 62 power supply, delivering up to 700W. 00730 VITA 62 and MIL-STD compliant 3U DC-DC supply provides up to 360W output power while operating with highest efficiency. 8” PITCH 1” PITCH 6U 1” PITCH 6U 1” PITCH. Operating temperature range: -40°C to +85°C. Max. MIL-STD Components. Meets ARINC 404A and ANSI/VITA 48. The XPedite8171 is an Intel® Atom™ E3800-based 3U VPX-REDI single board computer available in conduction- and air-cooled configurations. Intel® Xeon® D-1700 Processor-Based Rugged. Conduction cooled 1 slot 3U VPX with integral 6 channel intelligent 400W power supply. 2 conduction cooled modules because of their established deployment track record. 5 Slot 3U VPX Conduction Cooled ATR VPX VITA 48 – Rugged Thermal Solution 5 Slot –3 Payload plus 2 Peripheral Intel 11th Tiger Lake W-11865MRE NVIDIA MXM RTX A4500(5888 CUDA) 28V DC Input MIL-461/1275/704 300W Payload By Forced-Air Cooled 600W Payload By Liquid Cooled Design to Meet MIL-STD 810, MIL-461/1275/704, MIL. Designed to ARINC 404A, the chassis accepts conduction-cooled modules in various architectures such as VME/64x, cPCI, VXS, VPX, and more. 5"L x 4. . 0, SATA, graphics, and RS. Extended Temperature, Extended. 84in (235mm) L 3-slot OpenVPX backplane designed to profile BKP3-CEN03-15. Convection, conduction and liquid cooled ATR enclosures support a wide-range of applications for Land, Air and Sea. Grabcad 3U Vita Card. We offer displays with various mounting options like Panel / Rack. > Forced air cooling FMC-4600 series > ATR compliant enclosure (1/2 ATR short) > 6-slot backplane. Rugged ATR chassis include conduction cooled VPX, air cooled VPX and liquid cooled VPX ATR solutions. The Air Transportation Rack is the standard form factor for aircraft board electronic equipment. Designed for 6U Conduction Cooled Boards; Machined Aluminum 6061-T6 Construction; Front Load Design; Circular Connectors, indicators, and controls on Side Panel; Supports 6U backplanes; Related products. Part of our 1400 Series of conduction cooled enclosures with air assist, the 1440 is designed to maintain safe operating temperatures for high slot count 3U VPX systems and may be used as a deployment or development chassis. Folder. 2 specifications Operating temperature range of -40ºC to +70ºC Low weight, ideal for applications where the weight is critical Backplane options for VME/64X, cPCI, VXS, VPX and custom Features a MIL 38999 type power connector with an integrated line filterDocumentation. ily of conduction cooled ATR enclosures. Rugged, conduction cooled 1 to 6 slot 3U VPX with 6 channel intelligent 400 Watt power supply. This ½ ATR platform is designed for use in harsh environments. conduction cooled chassis for VPX and including ATR and ARINC 600 enclosures. ATR Chassis. Standard VME Outputs 5V, 3. USA (916) 297-0020 Canada (519) 885-5775 Email: sales@pixustechnologies. 10U VME64X Ground Mbile Rugged Enclosure. Form Factor: Custom Chassis Type: Custom Number of Slots: 2 Dimensions: 5. DDR5, DDR4 or other memory options. View product Compare. Extended Temperature, Extended shock & vibration. OpenVPX Ready. 5-slot, 6U OpenVPX (VITA 65) backplane, 1-in pitch. All ATR chassis are designed for plug in cards in alignment with the SOSA technical standard. 0 A/B channel is galvanically isolated and supports up to 1 Mbps. It supports up to two 0. The hybrid (convection and conduction) cooling system provides superior performance and a wide operational temperature range of -32C to 65C. Part No. VPX 3U Load Board - Conduction cooled: LXH0000840. 00720 VITA 62 and MIL-STD compliant 3U DC-DC supply provides up to 400W output power while operating with highest efficiency. 3U/6U (VPX / cPCI/ VME) Backplane Options. However, as module power continues to increase, VITA 48. The Chassis Manager is VITA 46. 87"W x 3. XPort3305 is a Conduction-Cooled XMC Networking Module with Dual 10 Gigabit Ethernet Interfaces and Rugged 10GBASE-SR Optical Connector. Atrenne Computing Solutions, a Celestica company, announces the release of the 717-SM Series ATR. Sub-½ ATR, Conduction- or Convection-Cooled Chassis Supporting Conduction-Cooled VPX and XMC or PMC Modules. and composite air-over conduction-cooled. This provides much more heat transfer than conduction alone. Elma's full line of convection cooled ATR (Air Transport Rack) enclosures offer a standardized, cost effective solution for VME, VME64x,cPCI, VXS, OpenVPX, and MicroTCA based applications. With so many highly ruggedized CompactPCI Serial. 1"L x 5. 2 module usage Configurable, modular ATR base design enables multi-program portability Forced air and conduction cooling for up to 850W of total power Dual 9 slot backplanes for up to 14 payload modules plus 2 each VITA 62 power modules and power hold up modules. VPX/OpenVPX, Other. Extended Description. from $1,995. Operating Temp. Block Diagram. with fast conversion between air and conduction cooled module guides and fast backplane replacement for easy reconfiguration in support of every stage of development. Our Open Frame systems are available with air cooled or conduction cooled variants and 600W ATX power. The AcroExpress ® VPX6600 is a high-performance 3U OpenVPX TM embedded single board computer based on the 6th Generation Skylake Intel ® Xeon ® E processor and PCH. The conduction-cooled unit provides a high degree of I/O front-end flexibility, with support for Gigabit Ethernet (GbE), 10GbE, Serial FPDP and other interfaces. Detailed 3/4 ATR, conduction-convection cooled. Open VPX is the architecture framework that defines system level VPX interoperability for multi-vendor, multi-module, integrated system environments. Engineers’ Guide to VME, VPX & VXS Annual Industry Guide Solutions for VME, VPX & VXS system engineers Featured Products Elma’s VME RAIDStor…The unit has been designed to house 3 off 3U VPX (VITA 48. Learn About Us. 63 MB; File Count 1; Create Date. This ¾ Long ATR ships with a 6U, 5-slot OpenVPX™ backplane and can accommodate other architectures such as 6U CompactPCI®, VME and VXS. VITA 48. ATR. 11 Tier 3 SOSA Aligned ChMC 79-V46-6-CHMC-CMC-S1. SIP’s convection, conduction and Hybrid cooled ATR enclosures support a wide range of rugged Airborne and Mobile deployed applications. Conduction Cooled OpenVPX/ SOSA ATR Chassis. Conduction cooling - cold plate Conduction cooled modules 75 500 Forced Air Conduction Cooled (internal fan or. The top-loaded enclosure accepts 6U double-Eurocard-format conduction-cooled modules constructed to meet the IEEE1101. The VTX985 is a dual slot 3U VPX chassis conduction cooled for two 3U VPX modules. 88 in. See Details. manufactures a variety of COTS modular designed conduction cooled chassis for VPX, VME, CPCI and CPCIexpress applications, including ATR and ARINC 600 enclosures. 1/2 ATR to ARINC 404A; Conduction cooled card cage to accommodate 6 x VPX slots on 1” pitch; 2 x 1” pitch custom power supply slots; High performance fan, commercial fan, or no fan option “Blown” sidewalls to maximise thermal performance The Extreme Engineering Solutions XPand6200 Series Sub-1/2 ATR, Conduction- or Convection-Cooled Chassis Supporting Conduction-Cooled VPX and XMC or PMC Modules is a true Commercial-Off-The-Shelf (COTS) Rugged system, supporting many 3U VPX, XMC, and PMC modules without modifications to the chassis or backplane to accommodate I/O. These rugged power supplies are available in 200W-1300W power. 30 in. View product Compare. Elma Electronic’s rugged OpenVPX ATR platform is designed to accommodate boards requiring liquid flow-through (LFT) cooling per the VITA 48. intelligent power. Table 1 below shows. Liquid Cooled ATR Enclosure. Single/dual cooled side walls. Rugged Rackmount. 88"W x 7. 4 standard. The WaveTherm 3U Conduction-Cooled Thermal Load-Board Module is a cost-effective solution for thermal testing of rugged or Mil-Spec enclosures and systems using wedge. The 3U VPX backplane uses standard 1. Derived directly from OpenVPX (VITA 65) and VPX (VITA 46), VNX+ follows the VPX trends, and is specifically designed to employ the essential tenants of OpenVPX for. 2. All CM ATRs surpassed MIL-STD-810F chassis environmental testing. The 8-slot forced-air, conduction-cooled unit incorporates slots for up to four conduction-cooled 3U VPX Payload Boards, 100GbE Switch, Clock Distribution Card, I/O-intensive SBC, and VITA 62 power supply. 8 in.